Find Multi Jet Water Meter, Multi Jet Brass Water Meter, Card Intelligent Water Meter on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.
Home > Products > Multi Jet Water Meter > Multi Jet Dry Type Plastic Cold Water Meter
Multi Jet Dry Type Plastic Cold Water Meter
  • Multi Jet Dry Type Plastic Cold Water Meter
Payment Type: L/C, T/T
Min. Order: 1
Basic Info

Model No.:  LXSC-15KS

Product Description Model NO.: LXSC-15KS Medium Temperature: Cold Water Counter Instructions: Digital and Analogue Application: Civil Medium Pressure: General Water Meter Stucture: Traditional Type: Multi Jet Dry Type Temperature: 0 Degrees Celsius to 50 Degrees Celsius Dial Reading: 0.00002L to 9999 Cubic Meter Connecting Standard: Bsp & NPT Trademark: Aimei Origin: China Install: Horizontal Level Measurement: Class B/Class C Nominal Diameter: 15mm Principle: Speed of Water Meter Work Environment: Dry Water Meter Material: Plastic Size: 15mm Working Pressure: 16 Bar Pressure Loss: 63 Length: 165mm/190mm Specification: Export Standard HS Code: 9028201000 Multi-jet Dry Type Vane Wheel Water Meter
It is a multi-jet super dry water meter for residential 
application in sizes 15mm-50mm for cold meter.

Features
Compact design with smaller meter body.
45° inclined register, hot wire tamper proof.
Copper-can register
Magnetic drive mechanism with anti-magnetic protection.
External regulation device

Standards Compliance 
ISO 4064
Directive 2004/22/EC on measuring instruments; 
the European  Standard EN14154+A1+A2: Water Meter; 
the International  Organization of Legal Metrology OIML R-49: 2006(E)

Optional Features 
Several lengths and connections available on request
Non return Valve
Reed switch option

Working Conditions
Water temperature: ≤50ºC for cold water meter  
Water pressure:   ≤1MPa or 1.6MPa optional
                  (10bar or 16bar option)

Accessories
Each meter has one set coupling optional: 2pcs coupling, 2pcs coupling nuts and 2pcs washers.

Installation requirements
The meter should be installed in horizontal position with the direction of the flow as 
indicated by the arrow cast in the meter body with the register face upwards.
Pipeline must be flushed before installation.
The meter should be constantly full of water during operation.

Maximum Permissible Error
In the lower zone from Qmin inclusive up to but excluding Qt is ±5%.
In the upper zone from Qt inclusive up to and including Qs is: cold water meter ±2%.
 
Multi Jet Dry Type Plastic Cold Water Meter


Multi Jet Dry Type Plastic Cold Water Meter

Contact us if you need more details on Meter Water. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Water Meter、Card Intelligent Water Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Multi Jet Water Meter